<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-14 14-18-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 57 dBuV VOLTAGE
Pilot RDS Phase Difference
6.5 kHz 3.9 kHz -10 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 71 kHz 10100 0,2574
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
5,7 dBr 6,92 dBr 8,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 14:18, 14.04.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (56 dBuV) Max at: 71 kHz MIN: 11 kHz % above 76 kHz: 0,2574 Acquired: 2025/04/14 14:17:15 Total samples: 10100 Equivalent time: 0:08:25 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,1 dBr MIN: 5,7 dBr AVE: 6,92 dBr % above 10,2 dBr: 0,0 Last value: 6,2 dBr (2025/04/14 14:17:14) Station: 96.90 MHz, signal: 4/5 (56 dBuV) 14:10 14:11 14:12 14:13 14:14 14:15 14:16 14:17 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality